The
Indicator DIL
shows on its Display the level of a liquid
contained in a vessel, thanks to the
following principle. Within the body of the
instrument there is a float including
special magnets; during the vertical float
movement, the magnets make small rollers
rotate within the nearby display; these
rollers are two-coloured face : they show
their red side when float goes up to their
height, and show their white side when goes
down.
In this way the
instrument assures a clear and easy
indication of the inside liquid, with many
advantages :
clearness
(the display is always limpid and visible,
even oily and dirty liquids),
legibility
(it is 100% legible, even from far and under
wide angles),
safety
(the instrument needs no periodic
servicing/cleaning and no kind of energy
from outside : it is a passive safety
instrument).
In addition to the local
indication, you can have also a remote
indication of the level, thanks to
Level Sensor
that may be placed on a side of the same
display; it generates an electric signal
(4÷20mA) directly proportional to the level
of liquid.
Furthermore it is
possible to complete the display with one or
more Alarms, electric or pneumatic, able to
trip when level reaches their heights; the
heights can be decided and changed by final
user also in a second time; so
the instrument performs a
triple function, as
Level Indicator, as
Level Transmitter
and as
Level Switch,
with an increased safety and circuit
simplicity.
They meet the PED and
ATEX standards.
APPLICATIONS.
Indication and operation at Max, Min or any
intermediate level on vessels containing
watery or chemical, corrosive, toxic, etc.
liquids; for normal-high-low temperatures,
and for pressures being very high too.
Body.
Cylindrical, stainless steel AISI 304, with
diameter and thickness corresponding to the
different application needs, such as
pressures and temperatures of fluid. With
liquids like water, stainless steel AISI 304
is able to operate with the
pressures/temperatures listed in ASME
standards; with other more corrosive liquids
it performs good resistance, but it is
necessary to evaluate each time the specific
operating conditions. Top and bottom ends of
body may have accessories too.
Connections to vessel.
Flanges, stainless steel AISI 304, size
1÷2”, ratings ANSI 150÷1500 psi. Sleeves,
stainless steel AISI 304, size ½”÷1½” with
possible mountings as per page 5. The most
popular connection-to-connection distances
are 178÷6000mm.
Display.
It is as high as the distance between
connections, and is placed in parallel to
the body. In it there is a series of small
rollers : while level rises, rollers hide
their white side and show their red one. The
contrary happens when level goes down.
Display is anodized Aluminium and is
protected by a transparent cover; it needs
no kind of supply.
Level Sensor.
It can be placed in parallel to the body. In
it there is an electric circuit with a
series of reed switches closing when are
invested by the magnetic field of the nearby
float. While level is rising, the switches
are closed step by step, with a consequent
generation of an electric signal being
directly proportional to the liuquid level;
the signal (4÷20mA) can be remote
transmitted by a common copper wire. As per
page 6 too.
Alarms.
They can be fixed at will along the left or
right side of display; they start up a
control when liquid reaches the level at
which they has been fixed : alarm for Max,
Min and/or any intermediate level.
•
Electric.
1 SPDT, reed contact, bistable, water-proof
IP65, within aluminium body; flame-proof
too. Load : 2÷250Vac-1A-60VA;
2÷250Vdc-0,5A-30W.
•
Pneumatic.
1 ON-OFF valve, with usage pressures :
2÷6Bar / 29÷87psi. Connection flange Display
Body with float and magnet Plate Inspection
flanges DIL Indicator Level sensor Allarms,
electric or pneumatic Ed. |